Danfoss Series 90 hydrostatic piston pump and motor can be applied together or combined with other products in a system to transfer and control hydraulic power.They are intended for closed circuit applications.

 

 

MODLE CODE

Feature Unit Frame
042 055 075 100 130 180 250
Displacement cm3/rev.
[in3]/rev.
42
[256]
55
[3.35]
75
(4.59]
100
[6.10]
130
(7.93]
180
(10.98)
250
[15.25]
Flow at rated speed
(theoretical)
l/min.
[US gal/min]
176
[46]
215
[57]
270
[71]
330
[87]
403
[106]
468
[124]
575
[160]
Torque at maximum
displacement (theoretical)
N*m/bar
[lbf.in/1000 psi]
0.67
[410]
0.88
[530]
1.19
[730]
1.59
[970]
2.07
[1260]
2.87
[1750]
3.97
[2433]
Mass moment of inertia of
rotating components
kg *m2
[slug*ft2]
0.0023
[0.0017]
0.0060
[0.0044]
0.0096
[0.0071]
0.0150
[0.0111]
0.023
[0.0170]
0.0380
[0.0280]
0.0650
[0.0479]
Weight (with control opt .MA) kg [lb] 34[75] 40 [88] 49[108] 68[150] 88[195] 136 [300] 154 [340]
Mounting (per ISO 3019-1) Flange
102-2 (SAE B)
Flange
127-4 (SAEC)
Flange
152-4 (SAE D)
Flange
165-4 (SAE E)
Rotation Right hand or Left hand rotation
Main ports:4-bolt split-flange
(per SAE J518 code 62)
mm
[in]
19.05
[0.75]
25.4
[1.0]
25.4
(1.0]
25.4
(1.0)
31.75
[125]
31.75
[1.25)
38.1
(1.5)
Main port configuration Twin poet Twin or side port Twin port
Case drain ports (SAE O-ring boss) UNF thread(in) 0.875-14 1.0625-12 1.0625-12 1.0625-12 1.3125-12 1.625-12 1625-12
Other ports SAE O-ring boss
Shafts Splined, and tapered shafts available
Auxiliary mounting SAE-A.B.C SAE-A.B.C.D SAE-A.B,CD.E

 

INSTALLATION SIZE

TECHNICAL PARAMETERS

Parameter Unit Frame
042 055 075 100 130 180 250
Input speed
Minimum min-3(rpm) 500 500 500 500 500 500 500
Rated Speed 4200 3900 3600 3300 3100 2600 2300
Maximum 4600 4250 3950 3650 3400 2850 2500

 

System pressure Maximum working pressure bar [psi] 450 [6525]
Maximum pressure 480 [6960]
Maximum low loop 45 [650]
Minimum low loop pressure 10 [145]
Charge pressure Minimum bar [psi] 18 [261]
Maximum 34 [493]
Control pressure Minimum (at corner power for EDC and FNR) bar [psi] 14 [203]
Minimum (at corner power for NFPE) 22 [319]
Maximum 40 [580]
Charge pump inlet pressure Rated bar (absolute) [in Hg vacuum] 0.7 [9]
Minimum (cold start) 02 [24]
Maximum bar [psi] 4.0 [58]
Case pressure Rated bar [psi] 3.0 [44]
Maximum 5.0 [73]
Lip seal external pressure Maximum bar [psi] 0.4 [15.8]

→Danfoss Series 90 Axial Piston Pump PDF

 

APLICAÇÃO


As bombas de deslocamento variável da série 90 são unidades compactas e de alta densidade de potência. Todos os modelos utilizam o conceito de pistão axial paralelo/deslizador em conjunto com uma placa oscilante inclinável para variar o deslocamento da bomba. A reversão do ângulo da placa oscilante inverte o fluxo de óleo da bomba e, portanto, inverte a direção de rotação da saída do motor. As bombas da série 90 incluem uma bomba de carga integral para fornecer
fluxo de óleo de reposição e resfriamento do sistema, bem como fluxo de fluido de controle. Elas também apresentam uma variedade de almofadas de montagem auxiliares para aceitar bombas hidráulicas auxiliares para uso em sistemas hidráulicos complementares. Uma família completa de opções de controle está disponível para atender a uma variedade de sistemas de controle (mecânicos, hidráulicos, elétricos). Os motores da Série 90 também usam o design de pistão/deslizador axial paralelo em conjunto com uma placa oscilante fixa ou inclinável. Eles podem receber/descargar fluido por qualquer porta; são bidirecionais. Eles também incluem um recurso de descarga de circuito opcional que fornece resfriamento e limpeza adicionais do fluido no circuito de trabalho.