Danfoss Series 90 hydrostatic piston pump and motor can be applied together or combined with other products in a system to transfer and control hydraulic power.They are intended for closed circuit applications.

MODLE CODE
| Feature | Unit | Frame | ||||||
|---|---|---|---|---|---|---|---|---|
| 042 | 055 | 075 | 100 | 130 | 180 | 250 | ||
| Displacement | cm3/rev. [in3]/rev. |
42 [256] |
55 [3.35] |
75 (4.59] |
100 [6.10] |
130 (7.93] |
180 (10.98) |
250 [15.25] |
| Flow at rated speed (theoretical) |
l/min. [US gal/min] |
176 [46] |
215 [57] |
270 [71] |
330 [87] |
403 [106] |
468 [124] |
575 [160] |
| Torque at maximum displacement (theoretical) |
N*m/bar [lbf.in/1000 psi] |
0.67 [410] |
0.88 [530] |
1.19 [730] |
1.59 [970] |
2.07 [1260] |
2.87 [1750] |
3.97 [2433] |
| Mass moment of inertia of rotating components |
kg *m2 [slug*ft2] |
0.0023 [0.0017] |
0.0060 [0.0044] |
0.0096 [0.0071] |
0.0150 [0.0111] |
0.023 [0.0170] |
0.0380 [0.0280] |
0.0650 [0.0479] |
| Weight (with control opt .MA) | kg [lb] | 34[75] | 40 [88] | 49[108] | 68[150] | 88[195] | 136 [300] | 154 [340] |
| Mounting (per ISO 3019-1) | Flange 102-2 (SAE B) |
Flange 127-4 (SAEC) |
Flange 152-4 (SAE D) |
Flange 165-4 (SAE E) |
||||
| Rotation | Right hand or Left hand rotation | |||||||
| Main ports:4-bolt split-flange (per SAE J518 code 62) |
mm [in] |
19.05 [0.75] |
25.4 [1.0] |
25.4 (1.0] |
25.4 (1.0) |
31.75 [125] |
31.75 [1.25) |
38.1 (1.5) |
| Main port configuration | Twin poet | Twin or side port | Twin port | |||||
| Case drain ports (SAE O-ring boss) | UNF thread(in) | 0.875-14 | 1.0625-12 | 1.0625-12 | 1.0625-12 | 1.3125-12 | 1.625-12 | 1625-12 |
| Other ports | SAE O-ring boss | |||||||
| Shafts | Splined, and tapered shafts available | |||||||
| Auxiliary mounting | SAE-A.B.C | SAE-A.B.C.D | SAE-A.B,CD.E | |||||
INSTALLATION SIZE







TECHNICAL PARAMETERS
| Parameter | Unit | Frame | ||||||
|---|---|---|---|---|---|---|---|---|
| 042 | 055 | 075 | 100 | 130 | 180 | 250 | ||
| Input speed | ||||||||
| Minimum | min-3(rpm) | 500 | 500 | 500 | 500 | 500 | 500 | 500 |
| Rated Speed | 4200 | 3900 | 3600 | 3300 | 3100 | 2600 | 2300 | |
| Maximum | 4600 | 4250 | 3950 | 3650 | 3400 | 2850 | 2500 | |
| System pressure | Maximum working pressure | bar | [psi] | 450 | [6525] | |
|---|---|---|---|---|---|---|
| Maximum pressure | 480 | [6960] | ||||
| Maximum low loop | 45 | [650] | ||||
| Minimum low loop pressure | 10 | [145] | ||||
| Charge pressure | Minimum | bar | [psi] | 18 | [261] | |
| Maximum | 34 | [493] | ||||
| Control pressure | Minimum (at corner power for EDC and FNR) | bar | [psi] | 14 | [203] | |
| Minimum (at corner power for NFPE) | 22 | [319] | ||||
| Maximum | 40 | [580] | ||||
| Charge pump inlet pressure | Rated | bar (absolute) | [in Hg vacuum] | 0.7 | [9] | |
| Minimum (cold start) | 02 | [24] | ||||
| Maximum | bar | [psi] | 4.0 | [58] | ||
| Case pressure | Rated | bar | [psi] | 3.0 | [44] | |
| Maximum | 5.0 | [73] | ||||
| Lip seal external pressure | Maximum | bar | [psi] | 0.4 | [15.8] | |
→Danfoss Series 90 Axial Piston Pump PDF
APLICAÇÃO
- Série 90 – tecnologia avançada
- Sete tamanhos de bombas de deslocamento variável
- Confiabilidade e desempenho comprovados
- Compacta, leve
- Vendas e serviços em todo o mundo
- Controles e sensores compatíveis com PLUS+1™
As bombas de deslocamento variável da série 90 são unidades compactas e de alta densidade de potência. Todos os modelos utilizam o conceito de pistão axial paralelo/deslizador em conjunto com uma placa oscilante inclinável para variar o deslocamento da bomba. A reversão do ângulo da placa oscilante inverte o fluxo de óleo da bomba e, portanto, inverte a direção de rotação da saída do motor. As bombas da série 90 incluem uma bomba de carga integral para fornecer
fluxo de óleo de reposição e resfriamento do sistema, bem como fluxo de fluido de controle. Elas também apresentam uma variedade de almofadas de montagem auxiliares para aceitar bombas hidráulicas auxiliares para uso em sistemas hidráulicos complementares. Uma família completa de opções de controle está disponível para atender a uma variedade de sistemas de controle (mecânicos, hidráulicos, elétricos). Os motores da Série 90 também usam o design de pistão/deslizador axial paralelo em conjunto com uma placa oscilante fixa ou inclinável. Eles podem receber/descargar fluido por qualquer porta; são bidirecionais. Eles também incluem um recurso de descarga de circuito opcional que fornece resfriamento e limpeza adicionais do fluido no circuito de trabalho.